Omron E5AN 96mm x 96mm Basic Temperature Controller - TC/RTD

Omron E5AN 96mm x 96mm Basic Temperature Controller - TC/RTD


Price: £197.00 (Excluding VAT at 20%)

Quantity:



Power Supply
100 to 240 VAC   
24 VAC/VDC   

Input Type
Thermocouple/RTD   

Control Output 1 + Functions
Relay Output (+£0.00)
12 VDC Voltage Output for Driving SSR (+£0.00)
4-20mA Current Output (+£45.00)
Relay Output + Heater Burnout Alarm (+£12.00)
12 VDC Voltage Output + Heater Burnout Alarm (+£12.00)
Relay Output + 3-Phase Heater Burnout Alarm (+£12.00)
Relay Output + Hybrid Relay (+£20.00)

Option Board

FREE 12 month product support and FREE configuration included as standard



The E5AN is from the latest temperature control family offering from Omron. The E5AN offers USB configuration and cloning using either the free ThermoMini or more advanced CX-Thermo software. It comes as standard with THREE auxiliary relay outputs in addition to the main output (one of which can be used as the "Cool" of a heat/cool controller) and clip on terminal covers.

This model is intended for us with thermocouple/RTD inputs.

Please note not all the variants shown on the Datasheet are available in the UK.




  • PV can be set to change colour (choice of 3) in alarm
  • High Accuracy
    • Thermocouple input: ±0.3% of reading
    • Pt input: ±0.2% of reading
    • Analogue input: ±0.2% FS
  • Main displays can alternate between PV/SV and indicate status of auto/manual, RUN/STOP and alarms
  • Output relay operation counter enables preventative maintenance to maximise plant uptime
  • Compatible with Support Software (CX-Thermo version 4.2 or higher)
  • Features a three-level display that simultaneously displays the PV, SV and MV
  • One touch operation with PF Key that can be assigned to auto/manual, RUN/STOP, or other functions/li>


  • Power Supply Voltage
    • Standard - 100 to 240 VAC, 50/60 Hz (unless D in model number which signifies: 24 VAC, 50/60 Hz; 24 VDC)
  • Operating voltage range
    • 85% to 110% of rated supply voltage
  • Power Consumption
    • 100 to 240 VAC: 10 VA
    • 24 VAC/VDC: 5.5 AV (24VAC)/4 W (24 VDC)
  • Sensor Input
    • Models with temperature inputs
    • Thermocouple: K, J, T, E, L, U, N, R, S, B, W, or PL II
    • Platinum resistance thermometer: Pt100 or JPt100
    • Infrared temperature sensor: 10 to 70°C, 60 to 120°C, 115 to 165°C, or 140 to 260°C
    • Voltage input: 0 to 50 mV
    • Models with analogue inputs
    • Current input: 0/4 to 20mA
    • Voltage input: 0/1 to 5V, or 0 to 10V
  • Input impedence
    • Current input: 150 Ω max., Voltage input: 1 MΩ min. (Use 1:1 connection when connecting the ES2-HB)
  • Control method
    • ON/OFF control or 2-PID control (with auto-tuning)
  • Control outputs
    • Relay output
      • SPST-NO, 250 VAC, 5 A (resistive load), electrical life: 100,000 operations, mininum load: 5V, 10mA
    • Voltage output (for driving SSR
      • Output voltage: 12 VDC ±15% (PNP), max. load current: 40 mA, with short-circuit protection circuit: Max. load current of 21 mA for control output 2
    • Current output
      • 4 to 20mA DC/0 to 20mA DC, load: 600 Ω max., resolution: approx. 10,000
    • Long-life relay output
      • SPST-NO, 250 VAC, 3A (resistive load), electrical life: 1,000,000 operations, minimum applicable load: 5V, 10 mA, leakage current: 5 mA max. (250 VAC, 60 Hz)
  • Auxiliary outputs
    • Number of outputs
      • 3
    • Output specifications
      • Relay output: SPST-NO, 250 VAC, 3 A (resistive load), electrical life: 100,000 operations, minimum applicable load: 5V, 10mA
  • Event Inputs
    • Number of inputs
      • 2
    • External contact input specifications
      • Contact input: ON: 1 kΩ max., OFF: 100 kΩ min.
      • Non-contact input: ON: Residual voltage: 1.5 V max., OFF: Leakage current: 0.1 mA max.
      • Current flow: Approx. 7 mA per contact
  • External Power Supply for ES1B
    • 12 VDC± 10%, 20mA, short-circuit protection circuit provided
  • Setting Method
    • Digital setting using front panel keys
  • Indication method
    • 11-segment digital display and individual indicators (7-segment display also possible) Character height: PV: 11.8mm, SV: 8.1mm, MV: 5.8mm.
    • Content of 3-level display: PV/SV/MV, PV/SV/multi-SP, or soak time remain*
    • Number of digits: 4 for PV, SV and MV
  • Multi SP
    • Up to four set points (SP0 to SP3) can be saved and selected using event inputs, key operations or serial communications
  • Bank switching
    • Not supported
  • Other functions
    • Manual output, heating/cooling control, loop burnout alarm, SP ramp, other alarm functions, heater burnout detection (including SSR failure and heater overcurrent detection), 40% AT, 100% AT, MV limiter, input digital filter, self-tuning, temperature input shift, run/stop, protection functions, control output ON/OFF counter, extraction of square root, MV change rate limit, logic operations, PV/SV status display, simple program, automatic cooling coefficient adjustment
  • Ambient operating temperature
    • -10 to 55°C (with no condensation or icing), for 3-year warranty: -10 to 50°C
  • Ambient operating humidity
    • 25% to 85%
  • Storage temperature
    • -25 to 65°C (with no condensation or icing)


Omron E5AN
Omron E5AN Dimensions

Accessories (Order seperately)

USB-Serial Conversion Cable
E58-CIFQ1
Omron E5CN USB-Serial Conversion Cable

Terminal Covers
E53-COV16 (Six Covers provided.)

E53-COV16 Terminal Cover

Waterproof Packing
Y92S-P4

Omron E5AN Waterproof Packing

Current transformers

E54-CT1
Omron E5CN E54=CT1 Current Transformer

E54-CT3
Omron E5CN E54=CT3 Current Transformer

E54-CT3 Accessory
Omron E5CN E54=CT3 Current Transformer Accessory

E54-CT1
Thru-current (Io) vs. Output Voltage (Eo) (Reference Values)


Maximum continuous heater current: 50 A (50/60 Hz)
Number of windings: 400±2
Winding resistance: 18±2 MΩ
Omron E5CN E54=CT1 Current Transformer Reference Values

E54-CT3
Thru-current (Io) vs. Output Voltage (Eo) (Reference Values)


Maximum continuous heater current: 120 A (50/60 Hz)
(Maximum continuous heater current for the Temperature Controller is 50 A.)
Number of windings: 400±2
Winding resistance: 8±0.8 MΩ
Omron E5CN E54=CT3 Current Transformer Reference Values




Application No.274
Energy-saving Measures for Solder Tank Idling
Registering two set values, one for idling and one for operation, in the E5AN Temperature Controller and using the multi-SP function enables saving energy during idling by externally changing the settings of the Temperature Controller.

Application 274



Application No.276
Error Detection in Control Loops
Use the G3PW Power Controller for temperature control of electric ovens.
Using the loop burnout alarm of the E5AN Temperature Controller now enables detecting heater burnout and errors when using current outputs.

Application 276



Controllers

Omron E5AN

1. Control Output 1
R: Relay output
Q: Voltage Output (for driving SSR)
C: Current output

2. Auxillary Outputs *2
3: Three outputs

3. Heater Burnout/SSR Failure, Control Output 2, or External Power Supply for ES1B
Blank: None
Q: Control output 2 (voltage output for driving SSR)
Y: Long-life relay output (hybrid)
H: Heater burnout/Heater short/Heater current detection (CT1)
HH: Heater burnout/Heater short/Heater current detection (CT2)
P: Power supply for sensor

4. Option
M: Option unit can be mounted

5. Input Type
T: Universal thermocouple/platinum resistance thermometer input
L: Analogue current/voltage input

6. Power Supply Voltage
Blank: 100 to 240 VAC
D: 24 VAC/VDC

8. Terminal Cover
-500: With terminal cover

9. Version
N: Available only to models released after January 2008

Option Units

Omron E5AN

1. Function
EN01: RS-232C communications
EN03: RS-485 communications
AKB: Event input



For more information on the Omron E5AN please refer to the following documentation:

Omron E5AN Datasheet (29/07/2011)
Click here to download the Omron E5AN datasheet in PDF format  

Omron E5AN User Manual (28/07/2011)
Click here to download the Omron E5AN user manual in PDF format  

Omron E5_N Series Communication Manual (26/07/2011)
Click here to download the Omron E5_N series communication manual in PDF format  

Omron E5_N Series Communications & Functions Manual (27/07/2011)
Click here to download the E5_N series communications and functions manual in PDF format  

Omron E5_N Series Basic User Manual (27/07/2011)
Click here to download the Omron E5_N series basic user manual in PDF format  

Online Catalogue | Omron | Omron Basic Temperature Controllers |  Omron E5AN 1/4 DIN Basic Temperature Controller for Thermocouple & RTD Inputs

CheckoutView Cart

Items:
Value:

Clearance Sale

Find us on the following social networks:

Like us on FacebookFollow us on TwitterFollow us on Linkedin

FREE CONFIGURATION & TECHNICAL SUPPORT INCLUDED WITH MOST ORDERS
Click here for more details

FREE ISS Ltd. Mug With All Orders Over £100.00 GBP