Online Catalogue | Omron | Omron Advanced Temperature Controllers |  Omron E5CN-H 1/16th DIN Advanced Temperature Controller

Quick Search
Main PagesHomeAbout ISSNewsServicesSupportNewsletterContact UsVacanciesHelpProduct PagesABBAOIPCALDruckElectro-SensorsElkorEurothermFlukeGefranLascarOmronProdigyRaytekSenecaShinkoStatusWest P SeriesWest N SeriesMiscellaneousClearance

Omron E5CN-H 1/16th DIN Advanced Temperature Controller

Online Catalogue | Omron | Omron Advanced Temperature Controllers |  Omron E5CN-H 1/16th DIN Advanced Temperature Controller

Omron E5CN-H 48mm x 48mm Advanced Temperature Controller

Omron E5CN-H 48mm x 48mm Advanced Temperature Controller


Price: £217.00 (Excluding VAT at 20%)

Quantity:



Input
Fully Universal - T/C, RTD & Linear   
Power Supply
STD 100/240 VAC   
LV 24 VDC/VAC   

Control Output 1
Relay Output (+£0.00)
Voltage Output (for driving SSR) (+£0.00)
Current Output (+£52.00)
Linear voltage output (+£92.00)

Option Boards

FREE 12 month product support and FREE configuration included as standard



The E5CN-H is the hi spec version of the E5CN from the latest temperature control family by Omron. The E5CN-H offers USB configuration and cloning using either the free ThermoMini or more advanced CX-Thermo software. It comes as standard with its main output and two relay alarms (one of which can be used as the "Cool" of a heat/cool controller) and a clip on terminal cover.
A range of plug in upgrade boards offer combinations of Dual Logic Inputs, RS485 comms, Logic Control O/P 2, Single & 3 phase CT inputs and Retransmission.



  • High-resolution display with 5 digits/0.01°C display in a compact controller (48 x 48 mm)
  • Easy configuration via free cloning and setting software (USB-serial conversion cable required)
  • PV can be set to change colour in alarm (red or green)
  • High-speed sampling cycle of 60 ms
  • High Accuracy
    • Thermocouple/Pt input: ±0.1% of reading
    • Analogue input: ±0.1% FS
  • Universal inputs on all models (thermocouple, PT or analogue input) to handle various sensors with one Controller
  • Main displays can alternate between PV/SV and indicate status of auto/manual, RUN/STOP and alarms
  • Output relay operation counter enables preventative maintenance to maximise plant uptime
  • Flexible contact outputs with logic operations (AND, OR and delays) set for support software (CX-Thermo Ver. 4.0)
  • IP66 front panel
  • Removable clear terminal cover included as standard


  • Power Supply Voltage
    • Standard - 100 to 240 VAC, 50/60 Hz (unless D in model number which signifies: 24 VAC, 50/60 Hz; 24 VDC)
  • Operating voltage range
    • 85% to 110% of rated supply voltage
  • Power Consumption
    • 100 to 240 VAC: 8.5 VA (max.) (ESCN-HR2 at 100 VAC: 3.0 VA)
    • 24 VAC/VDC: 5.5 VA (24V/23.5W (24Vdc) (max.) (E5CN-HR2D at 24 VAC: 2.7 VA)
  • Sensor Input
    • Any of the following can be selected (i.e., fully universal input).
    • Thermocouple: K, J, T, E, L, U, N, R, S, B, W, or PL II
    • Platinum resistance thermometer: Pt100 or JPt100
    • Current input: 0/4 to 20mA
    • Voltage input: 0/1 to 5V, or 0 to 10V
  • Input impedence
    • Current input: 150 Ω max., Voltage input: 1 MΩ min. (Use 1:1 connection when connecting the ES2-HB)
  • Control method
    • ON/OFF control or 2-PID control (with auto-tuning)
  • Control outputs
    • Relay output
      • SPST-NO, 250 VAC, 3A (resistive load), electrical life: 100,000 operations, mininum load: 5V, 10mA
    • Voltage output (for driving SSR
      • Output voltage: 12 VDC ±15% (PNP), max. load current: 21 mA, with short-circuit protection circuit
    • Current output
      • 4 to 20mA DC/0 to 20mA DC, load: 600 Ω max., resolution: approx. 10,000
    • Linear voltage output
      • 0 to 10 VDC (load: 1KΩ min.), Resolution: Approx 10,000
  • Auxiliary outputs
    • Number of outputs
      • Two max.
    • Output specifications
      • Relay output: SPST-NO, 250 VAC, 3A (resistive load), electrical life: 100,000 operations, minimum applicable load: 5V, 10mA
  • Event Inputs
    • Number of inputs
      • 2
    • External contact input specifications
      • Contact input: ON: 1 kΩ max., OFF: 100 kΩ min.
      • Non-contact input: ON: Residual voltage: 1.5 V max., OFF: Leakage current: 0.1 mA max.
      • Current flow: Approx. 7 mA per contact
  • Logic operations
    • Number of operations
      • 8 max. (combinations can be made using work bits
    • Operations
      • Logic operation: Any of the following four patterns can be selected. The input status may be inverted. (A and B) or (C and D), (A or C) and (B or D), A or B or C or D, A and B and C and D (A, B, C and D are four inputs.)
      • Delay: ON delay or OFF delay for the results of the logic operation given above. Setting time: 0 to 9999 s or 0 to 9999 min
      • Output inversion: Possible
    • Outputs
      • One work bit per operation
    • Work bit assignments
      • Any of the following can be assigned to up to eight work bits (logic operation results): Event input operations, auxiliary outputs or control outputs
  • Transfer Outputs
    • Number of outputs
      • 1 max.
    • Output specifications
      • Current output: 4 to 20 mA DC, Load 600 Ω max., resolution at 4 to 20 mA: Approx. 10,000
  • RSP Input
    • Not supported
  • Setting method
    • Display setting using front panel keys
  • Indication method
    • 11-segment digital display and individual indicators (7-segment display also possible) Character height: PV: 11mm, SV: 6.5mm
  • Bank switching
    • Supported (number of banks: 8). Local SP, alarm settings, PID sets (PID constants, MV upper limit, MV lower limit etc.)
  • Other functions
    • Manual output, heating/cooling control, loop burnout alarm, SP ramp, other alarm functions, heater burnout detection, 40% AT, 100% AT, MV limiter, input digital filter, self-tuning, temperature input shift, run/stop, protection functions, control output ON/OFF counter, extraction of square root, MV change rate limit, logic operations, PV/SV status display, simple program, automatic cooling coefficient adjustment
  • Ambient operating temperature
    • -10 to 55°C (with no condensation or icing), for 3-year warranty: -10 to 50°C
  • Ambient operating humidity
    • 25% to 85%
  • Storage temperature
    • -25 to 65°C (with no condensation or icing)


E5CN-H
Omron E5CN-H  Dimensions
Accessories (Order seperately)

USB-Serial Conversion Cable
E58-CIFQ1
Omron E5CN USB-Serial Conversion Cable

Terminal cover
E53-COV17
Omron E5CN Terminal Cover

Current transformers

E54-CT1
Omron E5CN E54=CT1 Current Transformer

E54-CT3
Omron E5CN E54=CT3 Current Transformer

E54-CT3 Accessory
Omron E5CN E54=CT3 Current Transformer Accessory

E54-CT1
Thru-current (Io) vs. Output Voltage (Eo) (Reference Values)


Maximum continuous heater current: 50 A (50/60 Hz)
Number of windings: 400±2
Winding resistance: 18±2 MΩ
Omron E5CN E54=CT1 Current Transformer Reference Values

E54-CT3
Thru-current (Io) vs. Output Voltage (Eo) (Reference Values)


Maximum continuous heater current: 120 A (50/60 Hz)
(Maximum continuous heater current for the Temperature Controller is 50 A.)
Number of windings: 400±2
Winding resistance: 8±0.8 MΩ
Omron E5CN E54=CT3 Current Transformer Reference Values

Adapter
Y92F-45


Note:
1.Use this Adapter when the panel has already been prepared for the E5B.
2.The Adapter is available only in black.
Omron E5CN Adapter

Mounted to E5CN
Omron E5CN Adapter Mounted

Note: all units in mm unless otherwise stated.


Application No.284
Time-sequence Temperature Management for Constant-temperature Tanks
Time-sequence temperature control for constant-temperature tanks is automatically controlled by the internal program.

Application 284

Application No.329
Ideal for Improving or Upgrading Facilities for Automotive Parts
The E5CN-H at 48 x 48 mm is compact and yet provides up to eight banks to register settings. You can change the bank with event inputs, communications, or the simple program function. Use it to meet your device upgrade needs.

Application 329

Application No.330
Ideal for Increasing the Control Performance of Industrial Hot Air Blowers
Displays are possible below the decimal point even for temperatures above 1,000°C. You can switch between three colors to clearly show the current status.

Application 330

Application No.331
Solves Problems in Electronic Component Assembly
High-speed sampling at 60 ms provides high-speed response and robust tuning. This improves the response to external disturbance, such as inconsistencies from air heaters.
Application 331

Application No.334
Ideal for High-precision Testing Equipment for Automotive Parts
The E5CN-H provides a compact size of 48 x 48 mm and measurement/control to five digits and 1/100°C.
A 24-bit AD converter improves measurement precision.
An output resolution of 10,000 enables high-precision control.
Displays to 1/100°C are also possible with thermocouples.

Application 334



Controllers

Omron E5CN

1. Type
H: Advanced

2. Control Output 1
R: Relay output
Q: Voltage Output (for driving SSR)
C: Current output
Y: Long-life relay output (hybrid) *1

3. Auxiliary Outputs
2: Two outputs

4. Option
M: Option Unit can be mounted.

5. Power Supply Voltage
Blank: 100 to 240 VAC
D: 24 VAC/VDC

6. Terminal Cover
-500: With terminal cover

Option Units

Omron E5CN

1.Applicable controller
CN: E5CN or E5CN-H

2. Function 1
Blank: None
Q: Control output 2 (voltage for driving SSR)
P: Power supply for sensor

3. Function 2
Blank: None
H: Heater burnout/SSR failure/ Heater overcurrent detection (CT1)
HH: Heater burnout/SSR failure/ Heater overcurrent detection (CT2)
B: Two event inputs
03: RS485 Communications
H03: Heater burnout/SSR failure/ Heater overcurrent detection (CT1) + RS485 Communications
HB: H03: Heater burnout/SSR failure/ Heater overcurrent detection (CT1) + Two event inputs
HH03: Heater burnout/SSR failure/ Heater overcurrent detection (CT2) + RS485 Communications

4. Version
N2: Applicable only to models released after January 2008


For more information on the Omron E5CN, please refer to the following documentation:

Omron ESCN-H Datasheet (28/07/2011)
Click here to download the E5CN-H datasheet in PDF format  

Omron E5_N-H Series Communications Manual
Click here to download the Omron E5_N-H series communications manual in PDF format  

Online Catalogue | Omron | Omron Advanced Temperature Controllers |  Omron E5CN-H 1/16th DIN Advanced Temperature Controller

CheckoutView Cart

Items:
Value:

Clearance Sale

Find us on the following social networks:

Like us on FacebookFollow us on TwitterFollow us on Linkedin

FREE CONFIGURATION & TECHNICAL SUPPORT INCLUDED WITH MOST ORDERS
Click here for more details

FREE ISS Ltd. Mug With All Orders Over £100.00 GBP